Power Input Replacement Instructions - SNR-7.5.1-W-035 MX12

Purpose This work instruction describes the process of replacing the Power Input on the MX12 centrifuges. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This document provides instructions for replacing the power input on an MX…

MX12 Interface Board - SNR-7.5.1-W-031

Purpose This work instruction describes the process to replace the User Interface Board on the MX12 Centrifuges. Required Equipment * User Interface Board (Part # 100919) Summary of Process This document provides instructions for replacing the user interface board. The procedure involves opening the unit, disc…

E8 Power Jack Replacement Instructions - SNR-7.5.1-W-023

Purpose This work instruction describes the process to replace a power jack for all versions of the E8 Centrifuge. Required Equipment * Power Jack Cable Assembly; E8 (Part # 100525) * #1 Philips Screwdriver Summary of Process The procedure involves unplugging the unit, removing the rotor and base/motor asse…

MX12 Lid Gasket Instruction - SNR-7.5.1-W-030

Purpose This work instruction describes the process for replacing the lid gasket of MX12 centrifuge units. Required Equipment * Lid Gasket (Part # from content) Summary of Process The procedure involves removing the old lid gasket and installing a new one to ensure proper function and seal of the centrifuge …

MX12 Hinge Instruction - SNR-7.5.1-W-021

Purpose This work instruction describes the process for replacing the hinge on MX12 centrifuge units. Required Equipment * Black Plastic Hinge; adjustable friction (Part # 101323) * Machine Screw; M4 X 0.7; 8mm; Black Oxide (Part # 100996) * 2.5mm hex driver Summary of Process The procedure involves turning …

CytoPrep Power Switch - SNR-7.5.1-W-038

Purpose This work instruction describes the process of replacing the Power Switch for both the CytoPrep-5 and CytoPrep-10 models. Required Equipment * Power Switch (Part # 100099) Summary of Process This document provides instructions for replacing the power switch on both the CytoPrep-5 and CytoPrep-10 units.…

MX5 Label Replacement Instructions - SNR-7.5.1-W-043

Purpose This work instruction describes the process for replacing the label of the MX5 Centrifuge. These repair instructions are valid for Revision G of the MX5 Centrifuge. Summary of Process This document provides instructions for replacing the label on an MX5 Centrifuge. The attached document provides a detail…

E8 Lid Repair Instructions - SNR-7.5.1-W-040

Purpose This work instruction describes the process for replacing the lid of all E8 Centrifuges. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process The procedure involves the complete process for replacing the lid on any E8 Centrifug…

E8 Digital Fuse Replacement Instructions - SNR-7.5.1-W-039

Purpose This work instruction describes the process for replacing the motor drive board fuse in the E8 Digital Centrifuge. These repair instructions are valid for the E8 Digital Centrifuge. Required Equipment * Fuse; 2A, 250V (Part # 100084) * 1/8” Flathead Screwdriver * #1 Philips Screwdriver Summary of Pr…

E8D Motor Drive Board Repair Instructions - SNR-7.5.1-W-010

Purpose This work instruction describes the process for replacing the soft start motor drive board in the E8 Digital Centrifuge. These instructions are valid for Revision J of the E8 Digital model. Required Equipment * Motor Drive Board (Part # 100480-C) * #1 Philips Screwdriver Summary of Process The repai…