MX5 Motor Repair Instructions - SNR-7.5.1-W-045

Purpose This work instruction describes the process of replacing the motor in an MX5 Centrifuge. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This document provides instructions for replacing the motor on an MX5 Centrifuge. The a…

MXU Speed Wheel Repair Instructions - SNR-7.5.1-W-013

Purpose This document provides instructions for replacing the MXU Speed Wheel on revision C MXU Digital Centrifuges. Required Equipment * Speed Sensor Wheel (Part # 101103) * Speed Sensor Hub (Part # 101104) * Speed Sensor Hub Stop (Part # 101105) * Blind Rivet, SS (Part # 100787) * Phillips Head Screwdri…

MX12 Interface Board - SNR-7.5.1-W-031

Purpose This work instruction describes the process to replace the User Interface Board on the MX12 Centrifuges. Required Equipment * User Interface Board * The full list of required equipment is not available in the provided document content. Summary of Process This procedure outlines the steps for replaci…

MX5 Fuse Repair Instructions - SNR-7.5.1-W-042

Purpose This work instruction describes the process of replacing the MX5 Fuse. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This document provides instructions for replacing the fuse on an MX5 Digital Centrifuge. The attached doc…

E8D Motor Drive Board Repair Instructions - SNR-7.5.1-W-010

Purpose This work instruction describes the process for replacing the soft start motor drive board in the E8 Digital Centrifuge. These instructions are valid for Revision J of the E8 Digital model. Required Equipment * Motor Drive Board (Part # 100480-C) * #1 Philips Screwdriver Summary of Process The repai…

E8F and E8V Lid Switch Repair Instructions - SNR-7.5.1-W-017

Purpose This work instruction describes the process for repairing the Lid Switch of the E8 Fixed and the E8 Variable centrifuges. These instructions are valid for Revision K of both centrifuge models. Required Equipment * Lid Safety Switch (Part # 101281) * Lid Switch Bracket (Part # 101282-B) * RHBS; 18-8;…

MX5 Motor Control Drive Board Repair Instructions - SNR-7.5.1-W-037

Purpose This work instruction describes the process for replacing the Motor Control Board on the MX5 Digital Centrifuge. The instructions apply to boards with part numbers 100918-B for 110V units and 101072 for 220V units. Required Equipment * Motor Control Board (Part # 100918-B for 110V or 101072 for 220V) Su…

MX12 Motor Replacement Instruction - SNR-7.5.1-W-034

Purpose This work instruction describes the process of replacing the motor in the MX12 Centrifuge. Required Equipment * Motor (Part # 100968-B or 100994-B) Summary of Process The procedure involves replacing the motor in an MX12 centrifuge. The attached document provides a step-by-step guide on how to perform …

MXU Speed Sensor Repair Instructions - SNR-7.5.1-W-012

Purpose This work instruction describes the process for replacing the MXU Speed Sensor on a revision C MXU Digital Centrifuge. Required Equipment * Speed Sensor (Part # 100271-C) * Phillips Head Screwdriver Summary of Process The repair process involves opening the centrifuge, removing the rotor and base plate,…

Ready Warm Power Switch - SNR-7.5.1-W-047

Purpose This work instruction describes how to replace the power switch for the Ready Warm Tissue Bath. These instructions are valid for revision 6. Required Equipment * Power Switch (Part # 100099) * 2mm Hex Wrench Summary of Process The repair procedure involves unplugging the unit, removing the screws, rep…