E8 Digital Fuse Replacement Instructions - SNR-7.5.1-W-039

Purpose This work instruction describes the process for replacing the motor drive board fuse in the E8 Digital Centrifuge. These repair instructions are valid for the E8 Digital Centrifuge. Required Equipment * Fuse; 2A, 250V (Part # 100084) * 1/8” Flathead Screwdriver * #1 Philips Screwdriver Summary of Pr…

E8 Lid Repair Instructions - SNR-7.5.1-W-040

Purpose This work instruction describes the process for replacing the lid of all E8 Centrifuges. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process The procedure involves the complete process for replacing the lid on any E8 Centrifug…

E8D Motor Drive Board Repair Instructions - SNR-7.5.1-W-010

Purpose This work instruction describes the process for replacing the soft start motor drive board in the E8 Digital Centrifuge. These instructions are valid for Revision J of the E8 Digital model. Required Equipment * Motor Drive Board (Part # 100480-C) * #1 Philips Screwdriver Summary of Process The repai…

MXU Speed Wheel Repair Instructions - SNR-7.5.1-W-013

Purpose This document provides instructions for replacing the MXU Speed Wheel on revision C MXU Digital Centrifuges. Required Equipment * Speed Sensor Wheel (Part # 101103) * Speed Sensor Hub (Part # 101104) * Speed Sensor Hub Stop (Part # 101105) * Blind Rivet, SS (Part # 100787) * Phillips Head Screwdri…

E8 Power Jack Replacement Instructions - SNR-7.5.1-W-023

Purpose This work instruction describes the process to replace a power jack for all versions of the E8 Centrifuge. Required Equipment * Power Jack Cable Assembly; E8 (Part # 100525) * #1 Philips Screwdriver Summary of Process The procedure involves unplugging the unit, removing the rotor and base/motor asse…

MX12 Hinge Instruction - SNR-7.5.1-W-021

Purpose This work instruction describes the process for replacing the hinge on MX12 centrifuge units. Required Equipment * Black Plastic Hinge; adjustable friction (Part # 101323) * Machine Screw; M4 X 0.7; 8mm; Black Oxide (Part # 100996) * 2.5mm hex driver Summary of Process The procedure involves turning …

MX12 Motor Replacement Instruction - SNR-7.5.1-W-034

Purpose This work instruction describes the process of replacing the motor in the MX12 Centrifuge. Required Equipment * Motor (Part # 100968-B or 100994-B) Summary of Process The procedure involves replacing the motor in an MX12 centrifuge. The attached document provides a step-by-step guide on how to perform …

MXU Speed Sensor Repair Instructions - SNR-7.5.1-W-012

Purpose This work instruction describes the process for replacing the MXU Speed Sensor on a revision C MXU Digital Centrifuge. Required Equipment * Speed Sensor (Part # 100271-C) * Phillips Head Screwdriver Summary of Process The repair process involves opening the centrifuge, removing the rotor and base plate,…

E8F and E8V Lid Switch Repair Instructions - SNR-7.5.1-W-017

Purpose This work instruction describes the process for repairing the Lid Switch of the E8 Fixed and the E8 Variable centrifuges. These instructions are valid for Revision K of both centrifuge models. Required Equipment * Lid Safety Switch (Part # 101281) * Lid Switch Bracket (Part # 101282-B) * RHBS; 18-8;…

Incubator Magnet Replacement Instructions - SNR-7.5.1-W-026

Purpose This work instruction describes the process to replace the door magnet of 10L, 20L, and 30L Incubators. Required Equipment * Stainless Steel Covered Magnet (Part # 101407) * 2 mm Hex Key Summary of Process The procedure involves opening the incubator door, unscrewing the old magnet with a 2mm Hex Key,…