MX5 Motor Repair Instructions - SNR-7.5.1-W-045

Purpose This work instruction describes the process of replacing the motor in an MX5 Centrifuge. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This document provides instructions for replacing the motor on an MX5 Centrifuge. The a…

MX5 User Interface Board Repair Instructions - SNR-7.5.1-W-041

Purpose This work instruction describes the process for replacing the User Interface Board (100919-C) of the MX5 Centrifuge. Required Equipment * User Interface Board (Part # 100919-C) Summary of Process This document provides instructions for replacing the user interface board of the MX5 Digital Centrifuge. T…

MXU Power Jack Repair Instructions - SNR-7.5.1-W-014

Purpose This work instruction describes the process for replacing the MXU Power Jack. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Power Jack Wiring Assembly (Part # 100300) * Phillips Head Screwdriver * Crescent Wrench Summary of Process The repair procedure…

E8 Digital Fuse Replacement Instructions - SNR-7.5.1-W-039

Purpose This work instruction describes the process for replacing the motor drive board fuse in the E8 Digital Centrifuge. These repair instructions are valid for the E8 Digital Centrifuge. Required Equipment * Fuse; 2A, 250V (Part # 100084) * 1/8” Flathead Screwdriver * #1 Philips Screwdriver Summary of Pr…

E8 Speed Wheel Replacement Instructions - SNR-7.5.1-W-028

Purpose This work instruction describes how to replace a speed wheel assembly, which includes two speed sensor hubs and one hub stop. Required Equipment * Speed Sensor Wheel (Part # 100482) * Speed Sensor Hub (Part # 100481) * Speed Sensor Hub Stop (Part # 100487) * #1 Philips Screwdriver Summary of Proc…

E8 Lid Latch Replacement Instructions - SNR-7.5.1-W-027

Purpose This document describes the procedure for replacing the E8 Lid Latch. These instructions are valid for E8V rev F, E8F rev D, and E8T rev F. Required Equipment * Latch (Part # 100073) * Cam Latch; 1.5” (Part # 100473) * #1 Screwdriver * Loc-Tite Blue 425 * Hios CL-6500 electric driver with #3 Phill…

E8 Power Jack Replacement Instructions - SNR-7.5.1-W-023

Purpose This work instruction describes the process to replace a power jack for all versions of the E8 Centrifuge. Required Equipment * Power Jack Cable Assembly; E8 (Part # 100525) * #1 Philips Screwdriver Summary of Process The procedure involves unplugging the unit, removing the rotor and base/motor asse…

MXU Power Switch Repair Instruction - SNR-7.5.1-W-009

Purpose This work instruction describes the process for replacing the power switch (100413) on a revision C MXU Digital Centrifuge. Required Equipment * Power Switch (Part # 100413) * Phillips Head Screwdriver Summary of Process The repair procedure involves removing the rotor and tube shields, inverting the …

E8F and E8V Motor Drive Board Repair Instructions - SNR-7.5.1-W-008

Purpose This work instruction describes the process for replacing the soft start motor drive board in the E8 Fixed Centrifuge and E8 Variable Centrifuge. These instructions are valid for Revision J of the E8 Fixed and E8 Variable models. Required Equipment * Motor Drive Board (Part # 101283) * #1 Philips Scr…

MX12 Motor Replacement Instruction - SNR-7.5.1-W-034

Purpose This work instruction describes the process of replacing the motor in the MX12 Centrifuge. Required Equipment * Motor (Part # 100968-B or 100994-B) Summary of Process The procedure involves replacing the motor in an MX12 centrifuge. The attached document provides a step-by-step guide on how to perform …