MX5 Label Replacement Instructions - SNR-7.5.1-W-043

Purpose This work instruction describes the process for replacing the label of the MX5 Centrifuge. These repair instructions are valid for Revision G of the MX5 Centrifuge. Summary of Process This document provides instructions for replacing the label on an MX5 Centrifuge. The attached document provides a detail…

E8D Motor Drive Board Repair Instructions - SNR-7.5.1-W-010

Purpose This work instruction describes the process for replacing the soft start motor drive board in the E8 Digital Centrifuge. These instructions are valid for Revision J of the E8 Digital model. Required Equipment * Motor Drive Board (Part # 100480-C) * #1 Philips Screwdriver Summary of Process The repai…

MXU Motor Control Board Repair Instructions - SNR-7.5.1-W-011

Purpose This work instruction describes the process for replacing the MXU Motor Control Board. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Motor Control Board (Part # 100484) * Needle Nose Pliers * Screwdriver Summary of Process The repair procedure invo…

E8 Speed Wheel Replacement Instructions - SNR-7.5.1-W-028

Purpose This work instruction describes how to replace a speed wheel assembly, which includes two speed sensor hubs and one hub stop. Required Equipment * Speed Sensor Wheel (Part # 100482) * Speed Sensor Hub (Part # 100481) * Speed Sensor Hub Stop (Part # 100487) * #1 Philips Screwdriver Summary of Proc…

E8 Power Jack Replacement Instructions - SNR-7.5.1-W-023

Purpose This work instruction describes the process to replace a power jack for all versions of the E8 Centrifuge. Required Equipment * Power Jack Cable Assembly; E8 (Part # 100525) * #1 Philips Screwdriver Summary of Process The procedure involves unplugging the unit, removing the rotor and base/motor asse…

Motor Control Board - SNR-7.5.1-W-032

Purpose This work instruction describes the process to replace the Motor Control Board on the MX12 Centrifuges. Required Equipment * User Interface Board Summary of Process This document provides instructions for replacing the MX12 Motor Control Board. The procedure involves removing the existing board and ins…

E8 Lid Latch Replacement Instructions - SNR-7.5.1-W-027

Purpose This document describes the procedure for replacing the E8 Lid Latch. These instructions are valid for E8V rev F, E8F rev D, and E8T rev F. Required Equipment * Latch (Part # 100073) * Cam Latch; 1.5” (Part # 100473) * #1 Screwdriver * Loc-Tite Blue 425 * Hios CL-6500 electric driver with #3 Phill…

MX5 Motor Repair Instructions - SNR-7.5.1-W-045

Purpose This work instruction describes the process of replacing the motor in an MX5 Centrifuge. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This document provides instructions for replacing the motor on an MX5 Centrifuge. The a…

E8F and E8V Lid Switch Repair Instructions - SNR-7.5.1-W-017

Purpose This work instruction describes the process for repairing the Lid Switch of the E8 Fixed and the E8 Variable centrifuges. These instructions are valid for Revision K of both centrifuge models. Required Equipment * Lid Safety Switch (Part # 101281) * Lid Switch Bracket (Part # 101282-B) * RHBS; 18-8;…

E8 Speed Tach Sensor Replacement Instructions - SNR-7.5.1-W-025

Purpose This work instruction describes how to replace a speed/tach sensor on the E8V Revision J and E8F Revision J centrifuge models. Required Equipment * IR Sensor (Part # 101070) * #1 Phillips screwdriver Summary of Process The repair procedure involves unplugging the unit and removing the rotor and ba…