Purpose This work instruction describes the process for replacing the MXU Power Jack. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Power Jack Wiring Assembly (Part # 100300) * Phillips Head Screwdriver * Crescent Wrench Summary of Process The repair procedure…
Purpose This work instruction describes the process of replacing the Power Switch for both the CytoPrep-5 and CytoPrep-10 models. Required Equipment * Power Switch (Part # 100099) Summary of Process This document provides instructions for replacing the power switch on both the CytoPrep-5 and CytoPrep-10 units.…
Purpose This work instruction describes the process of replacing the Power Switch (100099) on the Slide Warmer. Required Equipment * Power Switch (Part # 100099) Summary of Process This document provides instructions for replacing the power switch on a Slide Warmer. The attached document contains the detailed …
Purpose This work instruction describes the process for replacing the MXU Solenoid. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Solenoid; 12V (Part # 100079) * Phillips head screwdriver * #7 nut driver or #7 socket with socket wrench Summary of Process The…
Purpose This work instruction describes the process for replacing the MXU Motor Control Board. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Motor Control Board (Part # 100484) * Needle Nose Pliers * Screwdriver Summary of Process The repair procedure invo…
Purpose This work instruction describes how to replace the power switch for the Ready Warm Tissue Bath. These instructions are valid for revision 6. Required Equipment * Power Switch (Part # 100099) * 2mm Hex Wrench Summary of Process The repair procedure involves unplugging the unit, removing the screws, rep…
Purpose This work instruction describes the process for replacing the power switch (100413) on a revision C MXU Digital Centrifuge. Required Equipment * Power Switch (Part # 100413) * Phillips Head Screwdriver Summary of Process The repair procedure involves removing the rotor and tube shields, inverting the …
Purpose This work instruction describes the process for replacing the label of the MX5 Centrifuge. These repair instructions are valid for Revision G of the MX5 Centrifuge. Summary of Process This document provides instructions for replacing the label on an MX5 Centrifuge. The attached document provides a detail…
Purpose This work instruction describes the process for replacing the MXU Fuse. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Fuse; 3A; 250V (Part # 100084) * 1/8” Flathead Screwdriver Summary of Process The procedure involves unplugging the unit, removing the mot…
Purpose This work instruction describes the process for replacing the lid gasket of MX12 centrifuge units. Required Equipment * Lid Gasket (Part # from content) Summary of Process The procedure involves removing the old lid gasket and installing a new one to ensure proper function and seal of the centrifuge …