Incubator Magnet Replacement Instructions - SNR-7.5.1-W-026

Purpose This work instruction describes the process to replace the door magnet of 10L, 20L, and 30L Incubators. Required Equipment * Stainless Steel Covered Magnet (Part # 101407) * 2 mm Hex Key Summary of Process The procedure involves opening the incubator door, unscrewing the old magnet with a 2mm Hex Key,…

E8 Power Switch Replacement Instructions - SNR-7.5.1-W-024

Purpose This work instruction describes how to replace a power switch for all versions of the E8 centrifuge. Required Equipment * Switch; power input; round body; illuminated red (Part # 100099) * #1 Philips Screwdriver Summary of Process The procedure involves unplugging the unit, removing the rotor and ba…

MX5 Motor Control Drive Board Repair Instructions - SNR-7.5.1-W-037

Purpose This work instruction describes the process for replacing the Motor Control Board on the MX5 Digital Centrifuge. The instructions apply to boards with part numbers 100918-B for 110V units and 101072 for 220V units. Required Equipment * Motor Control Board (Part # 100918-B for 110V or 101072 for 220V) Su…

E8 Speed Tach Sensor Replacement Instructions - SNR-7.5.1-W-025

Purpose This work instruction describes how to replace a speed/tach sensor on the E8V Revision J and E8F Revision J centrifuge models. Required Equipment * IR Sensor (Part # 101070) * #1 Phillips screwdriver Summary of Process The repair procedure involves unplugging the unit and removing the rotor and ba…

Power Input Replacement Instructions - SNR-7.5.1-W-035 MX12

Purpose This work instruction describes the process of replacing the Power Input on the MX12 centrifuges. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This document provides instructions for replacing the power input on an MX…

MXU Solenoid Repair Instructions - SNR-7.5.1-W-015

Purpose This work instruction describes the process for replacing the MXU Solenoid. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Solenoid; 12V (Part # 100079) * Phillips head screwdriver * #7 nut driver or #7 socket with socket wrench Summary of Process The…

MX5 Lid Latch Repair Instructions - SNR-7.5.1-W-044

Purpose This work instruction describes the process of replacing the MX5 lid latch. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process The repair procedure involves replacing the lid latch on an MX5 Digital Centrifuge. The attached doc…

MXU Speed Wheel Repair Instructions - SNR-7.5.1-W-013

Purpose This document provides instructions for replacing the MXU Speed Wheel on revision C MXU Digital Centrifuges. Required Equipment * Speed Sensor Wheel (Part # 101103) * Speed Sensor Hub (Part # 101104) * Speed Sensor Hub Stop (Part # 101105) * Blind Rivet, SS (Part # 100787) * Phillips Head Screwdri…

MX5 Fuse Repair Instructions - SNR-7.5.1-W-042

Purpose This work instruction describes the process of replacing the MX5 Fuse. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This document provides instructions for replacing the fuse on an MX5 Digital Centrifuge. The attached doc…

MXU Speed Sensor Repair Instructions - SNR-7.5.1-W-012

Purpose This work instruction describes the process for replacing the MXU Speed Sensor on a revision C MXU Digital Centrifuge. Required Equipment * Speed Sensor (Part # 100271-C) * Phillips Head Screwdriver Summary of Process The repair process involves opening the centrifuge, removing the rotor and base plate,…