Purpose This work instruction describes the process for replacing the MXU Power Jack. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Power Jack Wiring Assembly (Part # 100300) * Phillips Head Screwdriver * Crescent Wrench Summary of Process The repair procedure…
Purpose This work instruction describes the process to replace a power jack for all versions of the E8 Centrifuge. Required Equipment * Power Jack Cable Assembly; E8 (Part # 100525) * #1 Philips Screwdriver Summary of Process The procedure involves unplugging the unit, removing the rotor and base/motor asse…
Purpose This work instruction describes how to replace a speed wheel assembly, which includes two speed sensor hubs and one hub stop. Required Equipment * Speed Sensor Wheel (Part # 100482) * Speed Sensor Hub (Part # 100481) * Speed Sensor Hub Stop (Part # 100487) * #1 Philips Screwdriver Summary of Proc…
Purpose This document describes the procedure for replacing the E8 Lid Latch. These instructions are valid for E8V rev F, E8F rev D, and E8T rev F. Required Equipment * Latch (Part # 100073) * Cam Latch; 1.5” (Part # 100473) * #1 Screwdriver * Loc-Tite Blue 425 * Hios CL-6500 electric driver with #3 Phill…
Purpose This work instruction describes the process for replacing the label of the MX5 Centrifuge. These repair instructions are valid for Revision G of the MX5 Centrifuge. Summary of Process This document provides instructions for replacing the label on an MX5 Centrifuge. The attached document provides a detail…
Purpose This work instruction describes the process of replacing the motor in an MX5 Centrifuge. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This document provides instructions for replacing the motor on an MX5 Centrifuge. The a…
Purpose This work instruction describes the process for replacing the User Interface Board (100919-C) of the MX5 Centrifuge. Required Equipment * User Interface Board (Part # 100919-C) Summary of Process This document provides instructions for replacing the user interface board of the MX5 Digital Centrifuge. T…
Purpose This work instruction describes the process for replacing the motor drive board fuse in the E8 Digital Centrifuge. These repair instructions are valid for the E8 Digital Centrifuge. Required Equipment * Fuse; 2A, 250V (Part # 100084) * 1/8” Flathead Screwdriver * #1 Philips Screwdriver Summary of Pr…
Purpose This work instruction describes the process for replacing the soft start motor drive board in the E8 Digital Centrifuge. These instructions are valid for Revision J of the E8 Digital model. Required Equipment * Motor Drive Board (Part # 100480-C) * #1 Philips Screwdriver Summary of Process The repai…
Purpose This work instruction describes the process for repairing the Lid Switch of the E8 Fixed and the E8 Variable centrifuges. These instructions are valid for Revision K of both centrifuge models. Required Equipment * Lid Safety Switch (Part # 101281) * Lid Switch Bracket (Part # 101282-B) * RHBS; 18-8;…