MXU Solenoid Repair Instructions - SNR-7.5.1-W-015
Purpose This work instruction describes the process for replacing the MXU Solenoid. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Solenoid; 12V (Part # 100079) * Phillips head screwdriver * #7 nut driver or #7 socket with socket wrench Summary of Process The…
-
CytoPrep Power Switch - SNR-7.5.1-W-038
Purpose This work instruction describes the process of replacing the Power Switch for both the CytoPrep-5 and CytoPrep-10 models. Required Equipment * Power Switch (Part # 100099) Summary of Process This document provides instructions for replacing the power switch on both the CytoPrep-5 and CytoPrep-10 units.…
-
Slide Warmer Power Switch - SNR-7.5.1-W-048
Purpose This work instruction describes the process of replacing the Power Switch (100099) on the Slide Warmer. Required Equipment * Power Switch (Part # 100099) Summary of Process This document provides instructions for replacing the power switch on a Slide Warmer. The attached document contains the detailed …
-
MXU Motor Control Board Repair Instructions - SNR-7.5.1-W-011
Purpose This work instruction describes the process for replacing the MXU Motor Control Board. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Motor Control Board (Part # 100484) * Needle Nose Pliers * Screwdriver Summary of Process The repair procedure invo…
-
Ready Warm Power Switch - SNR-7.5.1-W-047
Purpose This work instruction describes how to replace the power switch for the Ready Warm Tissue Bath. These instructions are valid for revision 6. Required Equipment * Power Switch (Part # 100099) * 2mm Hex Wrench Summary of Process The repair procedure involves unplugging the unit, removing the screws, rep…
-
Tissue Bath Repair Instructions - SNR-7.5.1-W-033
Purpose These repair instructions provide sequential details for the complete disassembly and reassembly process for the Ready Warm Tissue Bath. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This document provides a detailed guide…
-
MXU Fuse Repair Instruction - SNR-7.5.1-W-007
Purpose This work instruction describes the process for replacing the MXU Fuse. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Fuse; 3A; 250V (Part # 100084) * 1/8” Flathead Screwdriver Summary of Process The procedure involves unplugging the unit, removing the mot…
-
MX5 Label Replacement Instructions - SNR-7.5.1-W-043
Purpose This work instruction describes the process for replacing the label of the MX5 Centrifuge. These repair instructions are valid for Revision G of the MX5 Centrifuge. Summary of Process This document provides instructions for replacing the label on an MX5 Centrifuge. The attached document provides a detail…
-
MX12 Lid Gasket Instruction - SNR-7.5.1-W-030
Purpose This work instruction describes the process for replacing the lid gasket of MX12 centrifuge units. Required Equipment * Lid Gasket (Part # from content) Summary of Process The procedure involves removing the old lid gasket and installing a new one to ensure proper function and seal of the centrifuge …
-
MX5 Fuse Repair Instructions - SNR-7.5.1-W-042
Purpose This work instruction describes the process of replacing the MX5 Fuse. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This document provides instructions for replacing the fuse on an MX5 Digital Centrifuge. The attached doc…