Ready Warm Power Jack - SNR-7.5.1-W-046

Purpose This document provides instructions for replacing the power jack for the Ready Warm Tissue Bath. These instructions are valid for revision 6 of the Ready Warm. Required Equipment * The full list of required equipment is not available in the provided document content. Summary of Process This work instru…

E8 Lid Latch Replacement Instructions - SNR-7.5.1-W-027

Purpose This document describes the procedure for replacing the E8 Lid Latch. These instructions are valid for E8V rev F, E8F rev D, and E8T rev F. Required Equipment * Latch (Part # 100073) * Cam Latch; 1.5” (Part # 100473) * #1 Screwdriver * Loc-Tite Blue 425 * Hios CL-6500 electric driver with #3 Phill…

E8 Digital Fuse Replacement Instructions - SNR-7.5.1-W-039

Purpose This work instruction describes the process for replacing the motor drive board fuse in the E8 Digital Centrifuge. These repair instructions are valid for the E8 Digital Centrifuge. Required Equipment * Fuse; 2A, 250V (Part # 100084) * 1/8” Flathead Screwdriver * #1 Philips Screwdriver Summary of Pr…

Motor Control Board - SNR-7.5.1-W-032

Purpose This work instruction describes the process to replace the Motor Control Board on the MX12 Centrifuges. Required Equipment * User Interface Board Summary of Process This document provides instructions for replacing the MX12 Motor Control Board. The procedure involves removing the existing board and ins…

MX5 Label Replacement Instructions - SNR-7.5.1-W-043

Purpose This work instruction describes the process for replacing the label of the MX5 Centrifuge. These repair instructions are valid for Revision G of the MX5 Centrifuge. Summary of Process This document provides instructions for replacing the label on an MX5 Centrifuge. The attached document provides a detail…

MXU Power Switch Repair Instruction - SNR-7.5.1-W-009

Purpose This work instruction describes the process for replacing the power switch (100413) on a revision C MXU Digital Centrifuge. Required Equipment * Power Switch (Part # 100413) * Phillips Head Screwdriver Summary of Process The repair procedure involves removing the rotor and tube shields, inverting the …

E8F and E8V Lid Switch Repair Instructions - SNR-7.5.1-W-017

Purpose This work instruction describes the process for repairing the Lid Switch of the E8 Fixed and the E8 Variable centrifuges. These instructions are valid for Revision K of both centrifuge models. Required Equipment * Lid Safety Switch (Part # 101281) * Lid Switch Bracket (Part # 101282-B) * RHBS; 18-8;…

E8T Motor Drive Board Repair Instructions - SNR-7.5.1-W-006

Purpose This document provides instructions for replacing the soft start motor drive board in the E8 Touch Centrifuge. These instructions are valid for E8 Touch Revisions A and B. Required Equipment * Motor Drive Board (Part # 101283) * #1 Philips Screwdriver Summary of Process The procedure involves unpluggi…

MXU Fuse Repair Instruction - SNR-7.5.1-W-007

Purpose This work instruction describes the process for replacing the MXU Fuse. These repair instructions are valid for revision C MXU Digital Centrifuges. Required Equipment * Fuse; 3A; 250V (Part # 100084) * 1/8” Flathead Screwdriver Summary of Process The procedure involves unplugging the unit, removing the mot…

Mx12 Lid Latch Repair - SNR-7.5.1-W-001

Purpose This work instruction describes the process for replacing the lid latch on MX12 centrifuge units. Required Equipment * Replacement Lid Latch Summary of Process This document provides instructions for replacing the lid latch on an MX12 centrifuge. The procedure involves the removal of the old latch an…